Detecting Cavitation And High Vane Pass Frequency For Pumps
Nanoprecise Sci Corp
The Condensate Cooling Water (CCW) pump, one of the critical pumps in maintaining steadystate operations, is a horizontal vane pump operating at up to 1650 m3/hr with a discharge pressure of 9 MPa (62 psi) at 986 rpm. Each day this pump is offline costs the plant $250,000 in lost revenue and each failure costs tens of thousands of dollars to execute an unplanned repair. Thus, Larsen & Toubro (L&T) really needed a predictive maintenance solution to detect faults at an early stage and provide a reliable prediction of Remaining Useful Life (RUL)
Detection of a Bearing Outer Race Failure on a critical pump saved downtime cost
Nanoprecise Sci Corp
The process condensate pump, one of the critical pumps in the manufacturing process, has a history of failures every 6 to 12 months. It is a centrifugal pump operating at 3000 rpm with a discharge pressure of 28 MPa (400 psi). Each day this pump is offline, it costs the plant as much as $145,000 in lost production and each failure costs tens of hundreds of dollars to execute an unplanned repair. Nanoprecise Sci Corp was asked to implement a predictive maintenance solution in order to detect faults at an early stage and provide a reliable prediction of Remaining Useful Life (RUL).
Automatic monitoring of acoustic emission saves catastrophic failure
Nanoprecise Sci Corp
Traditional measurement tools are ineffective when it comes to slowly rotating equipment. There are faults like Bearing Failure, Ring Plugging, Gear Tooth Crack and many more which can lead to the shutdown of machines. 1 minute of downtime cost the company $10. RingPluggingis a very common issue which Pinnacle Pellet was facing very frequently due to diverse feed quality into the machines. Product ring plugging can be detected as sound levels increase in specific roller bearings.