Download PDF
Remote Monitoring and Controlling of Greenhouses
Technology Category
- Automation & Control - Supervisory Control & Data Acquisition (SCADA)
- Sensors - Camera / Video Systems
- Sensors - Humidity Sensors
- Sensors - Temperature Sensors
Applicable Industries
- Agriculture
Applicable Functions
- Process Manufacturing
Use Cases
- Smart Irrigation
The Challenge
For people who live and work in big cities, growing their own fruits and vegetables is a dream which is often difficult to realize. But how about renting a greenhouse, and being able to remotely plant seeds, spray water and apply fertilizers through a webpage, and then watching how your crops are growing via streaming video from an IP camera while you occasionally pay a physical visit to your plants at the weekends or holidays to harvest and cook your vegetables at a feast? A group of young Taiwanese entrepreneurs are making their own, and other people’s dreams come true by establishing greenhouse plots for rent. Leveraging the latest Advantech technologies and features provided by the ADAM-6200 series Ethernet I/O series and WebAccess 8.0 HMI/SCADA software, they’ve created a greenhouse automation and remote monitoring solution from which their customers can control and monitor the environment via a virtual dashboard on a computer, smartphone or other web-based device in real time.
The Solution
The customer divided their greenhouses into smaller rental compartments, which meant that each section needed an independent set of agro-controller systems, including sensors (for temperature, humidity, soil pH, and more), IP cameras, automatic water sprays, fans, etc. What they needed from Advantech included: relay modules to enable remote control over actuators of equipment such as water sprays and fans; data acquisition modules to read and transmit sensor data; and HMI-SCADA software to help realize remote monitoring and control and produce user interfaces.
System Implementation:
About 40 Advantech ADAM-6266s were deployed for relay controls, and nearly 20 ADAM-6217s were deployed for reading and collecting data from sensors. Since each of these modules have multiple channels, each of them is capable of monitoring several compartments each operated by different persons at the same time. ADAM-6200s have integrated Ethernet switches and can connect to each other in a “daisy chain” topology without the need to connect extra Ethernet switches. Meanwhile, because this topology, it can save the expense of physical wires. So that their customers can monitor the exact status of their gardens, our customer installed the latest version of WebAccess HMI/SCADA software, which incorporates Advantech’s hardware monitoring and diagnosis firmware/software package SUSIAccess, so that they can remotely monitor the CPU temperature, fan speed and other hardware parameters in easy and lower-cost system management and maintenance. Since the ADAM-6200 and WebAccess 8.0 support the latest HTML5 web language and RESTful webpage architectural style, our customer is able to use the Advantech-designed Widget Library and Dashboard Editor to easily customize their desired cross-platform dashboard page, to display dynamic data on end users’ devices (PC, iPad, smartphone, etc).
Technology Deployed:
ADAM-6217: 8-ch Isolated Analog Input Modbus TCP Module
ADAM-6266: 4-ch Relay Output Modbus TCP Module with 4-ch DI
Advantech WebAccess: Browser-based HMI/SCADASoftware
System Implementation:
About 40 Advantech ADAM-6266s were deployed for relay controls, and nearly 20 ADAM-6217s were deployed for reading and collecting data from sensors. Since each of these modules have multiple channels, each of them is capable of monitoring several compartments each operated by different persons at the same time. ADAM-6200s have integrated Ethernet switches and can connect to each other in a “daisy chain” topology without the need to connect extra Ethernet switches. Meanwhile, because this topology, it can save the expense of physical wires. So that their customers can monitor the exact status of their gardens, our customer installed the latest version of WebAccess HMI/SCADA software, which incorporates Advantech’s hardware monitoring and diagnosis firmware/software package SUSIAccess, so that they can remotely monitor the CPU temperature, fan speed and other hardware parameters in easy and lower-cost system management and maintenance. Since the ADAM-6200 and WebAccess 8.0 support the latest HTML5 web language and RESTful webpage architectural style, our customer is able to use the Advantech-designed Widget Library and Dashboard Editor to easily customize their desired cross-platform dashboard page, to display dynamic data on end users’ devices (PC, iPad, smartphone, etc).
Technology Deployed:
ADAM-6217: 8-ch Isolated Analog Input Modbus TCP Module
ADAM-6266: 4-ch Relay Output Modbus TCP Module with 4-ch DI
Advantech WebAccess: Browser-based HMI/SCADASoftware
Related Case Studies.
Case Study
Intelligent Farming with ThingWorx Analytics
Z Farms was facing three challenges: costly irrigation systems with water as a limited resource, narrow optimal ranges of soil moisture for growth with difficult maintenance and farm operators could not simply turn on irrigation systems like a faucet.
Case Study
Greenhouse Intelligent Monitoring and Control Solution
Farming Orchids is the most successful form of precision farming in Taiwan, and also the most exported flower. Orchids need a specific temperature and humidity conditions to grow and bloom, and its flowering time may not be in line with market demands, so the price collapses when there is overproduction. Therefore, some farmers began to import automated greenhouse control systems for breeding and forcing, which not only improves quality, but also effectively controls the production period and yield to ensure revenue. In 2012, an orchid farmer built a Forcing Greenhouse of about 200 pings (approximately 661 Square Meters) in Tainan, Taiwan. The system integrator adopted Advantech’s APAX-5000 series programmable automation controllers to build the control platform, coupled with Advantech WebAccess HMI/SCADA software, to achieve cloud monitoring. The staff of the orchid field can monitor important data anytime via smart phone, iPad, and other handheld devices, and control the growth and flowering conditions. System requirements: In the past, most environmental control systems of orchid greenhouses in Taiwan used PLCs (Programmable Logic Controller) with poorscalability and control, and could not be connected to the Internet formonitoring from the cloud. For advanced database analysis and networking capability, the PC platform must be adopted. Therefore, PAC Systems (Programmable Automation Controller) with both PLC programming capabilities andPC functions is a better choice.The environmental control of the Orchid greenhouse switches on and off devices like fan, shade net, cooling/heat pump, liquid flow control, water-cooling wall etc. It is controlled by a control panel of electric controllers, and is driven by a motor, to adjust the greenhouse temperature, humidity, and other environmental conditions to the set parameters.
Case Study
Enabling Internet of Things Innovation in Agriculture
DigiBale, wanted to apply technology know-how and IP from implementations successfully to more agriculture sectors including cotton, forestry, sugarcane and cattle. However, farmers and growers still have worries about the connected technology.
Case Study
Precision beekeeping with wireless temperature monitoring
Honeybees are insects of large economic value and provide a vital service to agriculture by pollinating a variety of crops. In addition, bees provide us with valuable products such as honey, beeswax, propolis, bee venom, etc. Monitoring of honeybee colony health, population, productivity, and environmental conditions affecting the colony health have always been exceedingly difficult tasks in apiculture. Research has shown that even small deviations (by more than 2°C) from the optimal temperatures have a significant influence on the development of the brood and the health of adult bees.