Download PDF
Efficient Design Procedures for Wideband, Low-profile Antennas Using Altair FEKO Electromagnetic Simulation Technology
Technology Category
- Networks & Connectivity - 5G
- Robots - Autonomous Guided Vehicles (AGV)
Applicable Industries
- Automotive
- Electrical Grids
Applicable Functions
- Product Research & Development
Use Cases
- Vehicle Performance Monitoring
- Virtual Reality
The Challenge
The Antenna Research Group (ARG) at the University of Colorado-Boulder was tasked with evaluating the bottom side of a vehicle as an alternative to more conventional antenna placement positions for mounting high-frequency VHF antenna systems. The challenge was to develop a procedure for evaluating the feasibility of bottom placement of HF-VHF antennas on military vehicles. Low profile concealed antennas are often desired for diverse applications across many military and commercial vehicle platforms. However, these tall antennas increase vehicles’ vertical clearance and constitute an easy to identify visual signature, which is undesirable. A vehicle underside can be considered as a viable alternative place for concealment, since it provides enough space to avoid extreme antenna miniaturization. The challenge was to assess and compare propagation losses for antennas at various vehicle positions.
About The Customer
The Antenna Research Group (ARG) at the University of Colorado-Boulder is a leading research center housed in the Department of Electrical, Computer, and Energy Engineering. ARG is committed to research directed toward antenna theory and design with emphasis on applications of electrically small antennas, simultaneous transmit and receive techniques, and wideband microwave and millimeter wave antennas for electronic attack, electronic support and communications. Under the direction of Dr. Dejan Filipovic, the ARG team has designed and delivered many wideband and narrowband antenna systems operating as low as 2 MHz and as high as 220 THz. The ARG at the University of Colorado Boulder has a 15-year history of dedication to antenna research and design. The research group has 8 post-doctoral research associates, 14 doctoral students, 2 undergraduate research students, and 2 research administrators. To date, the group has published over 225 peer reviewed journal publications, conference papers, short courses, and tutorials.
The Solution
The solution was to apply FEKO electromagnetic field simulation methods to assess bottom placement antenna performance. The numerical study was conducted with the vehicle model. An all metallic structure was assumed to be a perfect electric conductor, whereas antenna sources were approximated as Hertzian electric dipoles placed 0.05 m away from the vehicle surface for top and bottom positions. FEKO accounts for the ground loss by means of Sommerfeld integrals implemented in the code. Three types of grounds including dry sand, asphalt and wet soil were considered. The ARG project team heavily relied on FEKO results to validate their analytical procedure for the propagation loss calculations and then use the developed FEKO models to accurately determine impact ranges for various antenna/platform systems. The performance of the vehicle mounted antennas at various locations was evaluated in terms of omnidirectionality, efficiency, and propagation loss.
Operational Impact
Quantitative Benefit
Related Case Studies.
Case Study
Integral Plant Maintenance
Mercedes-Benz and his partner GAZ chose Siemens to be its maintenance partner at a new engine plant in Yaroslavl, Russia. The new plant offers a capacity to manufacture diesel engines for the Russian market, for locally produced Sprinter Classic. In addition to engines for the local market, the Yaroslavl plant will also produce spare parts. Mercedes-Benz Russia and his partner needed a service partner in order to ensure the operation of these lines in a maintenance partnership arrangement. The challenges included coordinating the entire maintenance management operation, in particular inspections, corrective and predictive maintenance activities, and the optimizing spare parts management. Siemens developed a customized maintenance solution that includes all electronic and mechanical maintenance activities (Integral Plant Maintenance).
Case Study
Hydro One Leads the Way In Smart Meter Development
In 2010, Ontario’s energy board mandated that time-of-use (TOU) pricing for consumers be available for all consumers on a regulated price plan. To meet this requirement, Hydro One needed to quickly deploy a smart meter and intelligent communications network solution to meet the provincial government’s requirement at a low cost. The network needed to cover Hydro One’s expansive service territory, which has a land mass twice the size of Texas, and its customers live in a mix of urban, rural, and remote areas, some places only accessible by air, rail, boat or snowmobile. Most importantly, the network needed to enable future enterprise-wide business efficiencies, modernization of distribution infrastructure and enhanced customer service. To meet these needs, Hydro One conceptualized an end-to-end solution leveraging open standards and Internet Protocols (IP) at all communication levels. The utility drew upon industry leaders like Trilliant to realize this vision.
Case Study
Monitoring of Pressure Pumps in Automotive Industry
A large German/American producer of auto parts uses high-pressure pumps to deburr machined parts as a part of its production and quality check process. They decided to monitor these pumps to make sure they work properly and that they can see any indications leading to a potential failure before it affects their process.